1、 Replacement and Cleaning of Filter for Huaquan Generator Set
Oil filter: Regularly clean the oil filter to prevent impurities from clogging and affecting the fluidity and lubrication effect of the oil. Replace as necessary to ensure the cleanliness of the engine oil.
Huaquan generator diesel filter: Regularly clean the diesel filter and its filter element to prevent impurities in diesel from entering the engine, affecting combustion efficiency and engine performance.
Air filter: Clean the air filter in a timely manner, replace the air filter element to prevent dust and impurities from entering the engine, and maintain the normal intake volume of the engine.
 
2、 Maintenance of Huaquan Generator Battery
Electrolyte inspection: Regularly check the electrolyte level of the battery to ensure that it is within the normal range, and promptly replenish distilled water.
Charging operation: Configure a high-quality charger and regularly perform equalization and float charging operations to maintain sufficient battery power.
Battery terminal cleaning: Clean the battery terminals to ensure that the battery wires are firmly connected and prevent battery failure caused by poor contact.
 
3、 Engine maintenance
Oil inspection and replacement: Regularly check the condition of the engine oil, including oil quality, level, temperature, and pressure, to ensure the lubrication effect of the oil. Regularly replace the engine oil and oil filter to prevent oil deterioration and filter blockage.
Diesel inspection: Regularly check the moisture content and impurities of diesel to prevent rust and damage caused by condensed water entering the fuel tank. Ensure the cleanliness and adequacy of diesel fuel.
Ignition system adjustment: For generator sets equipped with ignition systems, it is necessary to regularly check and adjust the spark plug clearance and ignition timing to ensure uniform ignition and improve combustion efficiency.
Huaquan generator set
4、 Maintenance of cooling system for Huaquan generator set
Pump and water tank inspection: Regularly check the condition of the pump, water tank, and water supply pipeline, clean scale and impurities, and ensure the cooling system's heat dissipation effect.
Water pipe joint inspection: Check whether the water pipe joints, water tank, and waterway are leaking, repair the leakage points in a timely manner, and prevent engine overheating caused by poor cooling.
 
5、 Maintenance of fuel and gas distribution system for Huaquan generator set
Fuel system cleaning: Regularly clean the fuel system, including the fuel filter, fuel pump, and inlet pipe, to ensure smooth fuel supply.
Valve system adjustment: Adjust the valve system, including valve clearance and valve timing, to ensure the normal intake and exhaust processes of the engine.
 
6、 Inspection of Control System for Huaquan Generator Set
Line connector inspection: Regularly check whether the control line connectors of the generator set are loose or damaged to ensure accurate transmission of control signals.
AVR module inspection: Check the working status of the automatic voltage regulator (AVR) module to ensure that it can regulate the voltage output normally and maintain voltage stability.
Huaquan generator set
7、 Precautions for long-term shutdown of Huaquan generator set
Regular trial operation: If the generator set is not used for a long time, regular trial operation should be carried out to check whether the oil level, coolant level, etc. are within a reasonable range, and record the relevant parameters of equipment operation.
Oil and antifreeze replacement: Ensure good quality of oil and antifreeze before starting, and replace if necessary.
Fuel system inspection: Check whether the fuel system is clean, whether the fuel is sufficient, and whether there is any oil leakage in the connecting pipelines.
 
In summary, the daily maintenance of Huaquan generator sets covers multiple aspects such as filters, batteries, engines, cooling systems, fuel and valve systems, control systems, and long-term shutdown precautions. Through regular maintenance and upkeep, it can be ensured that the generator set can operate reliably at critical moments and extend its service life.
More information on Huaquan generator sets:http://www.wfhqfdjz.com/

Sales hotline: +86 15905360672
WeChat customer service: +86 15905360672
Email address: huaquan@huaquanpower.com
Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone, Weifang City, Shandong Province
Company Name:SHANDONG HUAQUAN POWER CO.,LTD